Emissions compliant engines

Stage V engines, ready to fit.

EU Stage V is the toughest emissions standard yet for off-road engines, and it’s what new machines in the UK and EU need today. We have 41 Stage V engines from Hatz, Lister Petter, Rehlko and Yanmar, from 3.4 kW to 105 kW, configured for your machine and backed by parts and people who know them.

See all Stage V engines What Stage V means
Stage V approved
41 Stage V engines on our site
3.4–105 kW from 1 to 4 cylinders
4 brands: Hatz, Lister Petter, Rehlko and Yanmar
17 also meet US Tier 4 Final

Why Stage V

Compliant now, and ready for what’s next.

Choosing a Stage V engine today saves a re-power, a rental swap or a lost contract later.

Ready for new machines

Engines placed on the market for new non-road machinery in the UK and EU must meet Stage V, so a Stage V engine keeps your machine sellable and compliant.

Welcome on more sites

Since January 2025, generators from 37 to 560 kW must meet Stage V anywhere in London. From 2030, all non-road machinery in that range will. Other cities and big contractors are heading the same way.

Cleaner, with proof

Stage V cuts soot to a fraction of older engines, and every engine carries type approval, so you have the paperwork when a client, a site manager or a tender asks for it.

Sold around the world

17 of our Stage V engines also meet US EPA Tier 4 Final, and some carry China IV and Bharat Stage V too, which helps if your machines are built for export.

Our Stage V range

All 41 engines, by power.

Click any engine for full specs, dimensions and a datasheet you can set up for your machine.

EnginePowerCylindersAftertreatmentAlso meets
Below 8 kW · 12 engines
Hatz 1B203.4 kW1None needed–
Yanmar L48V3.4 kW1DOC + EGR–
Hatz 1B30VE4.2 kW1None neededUS Tier 4 Final
Hatz 1B30E4.5 kW1None neededUS Tier 4 Final
Yanmar L70V4.8 kW1EGR–
Hatz 1B305 kW1None needed–
Yanmar L100V6.8 kW1EGR–
Yanmar L100V66.8 kW1EGR–
Hatz 1D427 kW1None needed–
Hatz 1D507.5 kW1None needed–
Hatz 1B507.9 kW1None needed–
Hatz 1B50E7.9 kW1None neededUS Tier 4 Final
8 to 19 kW · 22 engines
Hatz 1D81C9.5 kW1None needed–
Hatz 1D8110.1 kW1None needed–
Hatz 1D90E10.5 kW1None neededUS Tier 4 Final
Rehlko KDW702 E53011 kW2EGR–
Hatz 1D9011.2 kW1None needed–
Hatz 1D90VE11.2 kW1None needed–
Rehlko KDW702 E53611.5 kW2EGRUS Tier 4 Final
Rehlko KDW702 E536A11.6 kW2EGR–
Rehlko KDW1003 E524A14 kW3EGR–
Rehlko KDW1003 E53014.8 kW3EGRUS Tier 4 Final
Rehlko KDW1003 E53617.7 kW3EGRUS Tier 4 Final
Rehlko KDW1003 E530A18 kW3EGR–
Hatz 3F35E18.4 kW3None neededUS Tier 4 Final
Hatz 3F4518.4 kW3None neededUS Tier 4 Final
Hatz 3F45E18.4 kW3None neededUS Tier 4 Final
Lister Petter LP311EVi118.5 kW3None needed–
Lister Petter LP311EVi218.5 kW3None needed–
Rehlko KDW1003 E536A18.8 kW3EGR–
Rehlko KDW1404 E53018.8 kW4EGR–
Rehlko KSD 1403NA18.9 kW3None neededBharat TREM V, China IV, US Tier 4 Final
Rehlko KSD 1403TC18.9 kW3None neededBharat TREM V, China IV, US Tier 4 Final
Rehlko KSD 1403TCA18.9 kW3None neededBharat TREM V, China IV, US Tier 4 Final
19 to 56 kW · 5 engines
Lister Petter LP322EVi144.8 kW3DOC + DPF + EGR–
Rehlko KDI-TCN 3404E5/2255.4 kW4DOC + DPF + EGRUS Tier 4 Final
Rehlko KDI-TCR 2504E5/2655.4 kW4DOC + DPF + EGRBharat TREM V, China IV, US Tier 4 Final
Lister Petter LP322EVi255.8 kW3DOC + DPF + EGR–
Lister Petter LP430EVi155.8 kW4DOC + DPF + EGR–
56 to 130 kW · 2 engines
Rehlko KDI-TCP 3404E5/22C75 kW4DOC + DPFUS Tier 4 Final
Rehlko KDI-TCP 3404E5/22105 kW4DOC + DPFUS Tier 4 Final

Aftertreatment is what each engine needs to meet Stage V: DOC is a diesel oxidation catalyst, DPF a diesel particulate filter and EGR exhaust gas recirculation. Most engines under 19 kW meet Stage V with no filter at all, which keeps them simple to service. Power figures are the manufacturer’s maximum ratings.

Filter the engine finder Ask which suits your machine

The rules

Stage V in plain English.

What the standard is, when it applies and what it means for the engine you choose.

What is Stage V?

Stage V is the European emissions standard for engines in non-road mobile machinery: diggers, dumpers, compressors, pumps, generators, mowers and the rest. It’s set by Regulation (EU) 2016/1628 and limits the carbon monoxide, hydrocarbons, nitrogen oxides and particulates an engine can put out for each kWh of work.

It’s the biggest step yet. For the first time it covers every power band, from the smallest single-cylinder engine up to big generator engines over 560 kW, and for engines between 19 and 560 kW it limits the number of soot particles as well as their weight. In practice, that means a particulate filter on those engines.

When did it start, and does it apply in the UK?

Stage V applied to engines placed on the market from 2019, and from 2020 for engines between 56 and 130 kW. In Great Britain the same Stage V limits apply, and engines need GB type approval, based on their EU approval, before they can be placed on the market. In Northern Ireland, EU or UK(NI) type approval applies.

The limits, by power band

Figures are grams per kWh of work, with particle number (PN) in particles per kWh.

Engine powerCOHC + NOxPMParticle number
Below 8 kW8.007.500.40–
8 to 19 kW6.607.500.40–
19 to 37 kW5.004.700.0151×10¹²
37 to 56 kW5.004.700.0151×10¹²
56 to 130 kW5.00HC 0.19, NOx 0.400.0151×10¹²
130 to 560 kW3.50HC 0.19, NOx 0.400.0151×10¹²

The jump at 19 kW is the one that matters most when you’re choosing. Below it, an engine can meet Stage V with good combustion and, on some, EGR. Above it, the particulate limit falls by more than 25 times and a particle-number limit arrives, so a DPF becomes the norm. If your machine sits close to 19 kW, it’s worth talking to us about which side of the line to choose.

What about generators?

Generator engines are covered too. In London, generators from 37 to 560 kW have had to meet Stage V anywhere in Greater London since 1 January 2025, and from 2030 all non-road machinery in that power range will need Stage V across the capital. More clients and main contractors now ask for Stage V on their sites wherever they are.

Our Fusion Series includes a Stage V range, from about 6 kVA to over 600 kVA. Tell us the load and the site, and we’ll match the set to the rules.

Replacing an engine in an older machine

The rules are different when you’re replacing an engine in a machine that’s already in service. In some cases a replacement engine doesn’t have to meet the latest stage, but that depends on the machine, its age and where it works. Send us the details of the machine and the engine that’s fitted now, and we’ll tell you your options, including a Stage V upgrade if it fits.

Questions

Good to know.

Anything else, call us on +44 (0) 1626 778 266.

Do I need a Stage V engine?

If you’re building new machinery to sell in the UK or EU, almost certainly. If you’re replacing an engine in a machine that’s already working, it depends on the machine and where it’s used. Tell us about it and we’ll check.

Do all Stage V engines have a DPF?

No. Most engines under 19 kW meet Stage V without a particulate filter, including every Hatz engine we list under 19 kW. Above 19 kW, the particle number limit means a DPF is usual. The table above shows what each of our engines uses.

Is a Stage V engine harder to maintain?

Not much. Engines with a DPF need the right low-ash oil and the occasional regeneration, which most do automatically while working. We stock the filters and service parts and can talk you through it.

Does Stage V apply to generators?

Yes. Generator engines have their own Stage V limits, and London requires Stage V for generators from 37 to 560 kW. Our Fusion Series includes Stage V sets.

Can I use a Stage V engine abroad?

Yes. 17 of our Stage V engines also meet US EPA Tier 4 Final, and some carry China IV and Bharat Stage V. Tell us the destination and we’ll confirm the paperwork.

Is Stage V the same as Tier 4 Final?

They’re close but not the same. Tier 4 Final is the US EPA standard. Many engines are certified to both, but you need the right approval for where the machine will be sold or used.

Get a quote

Need a Stage V engine or generator?

Tell us the machine, the power and where it’ll work. We’ll recommend a compliant engine or set and send you the datasheet.

Ask for a quote Call +44 (0) 1626 778 266